EASi 4.5m Antenna Installation Kit
1
EASi 4.5 Meter Antenna Installation Kit
1 Introduction
This document describes an installation kit that is used in conjunction with the RC2K90INT-2E interface
box which allows an RC2000 antenna controller to operate an EASi 4.5m meter antenna. Efficient Antenna
Systems inc. (EASi) may be contacted at WWW.EASiSat.COM . The EASi antenna uses 1 ½ HP 90 VDC
motors, so the larger version of the interface box is used. The heater option is normally included in this
version. The following issues are addressed in this paper:
• The AC power requirements of the interface box.
• Recommended types of cable that may be used to connect the RC2000 antenna controller to the
interface box.
• A controller - interface box - antenna wiring diagram.
• RC2000EASi software configuration parameters.
• A conduit/wiring schedule.
• A Bill of Materials.
2 AC Power
The interface box is housed in a NEMA 4 weatherproof enclosure. In the Standard configuration, 120 Volt
AC power must be provided at the antenna pad. All ungrounded AC line supply conductors must be fused
or protected with circuit breakers, do not fuse neutral or grounded conductors. A 25 or 30 amp circuit
breaker is sufficient. In addition, an AC emergency disconnect conforming to the NEC (National Electric
Code) and other applicable electrical codes must be provided at the antenna and be readily accessible to
personnel in the vicinity of the antenna.
The AC line input of the interface box will be pre-wired with 10 feet of 12/3 cable. The interface box has a
straight 1/2” conduit fitting appropriate for flexible steel reinforced liquid tight conduit of which 8 feet is
supplied. The user should make provisions to accept this type of conduit on the electrical box which houses
the emergency disconnect. Alternatively, the user can replace the liquid tight conduit fitting with a different
type of conduit fitting. The interface box is punched with a 7/8” diameter hole for the liquid tight conduit
fitting.
3 Antenna Controller to Interface Box Interconnect Cable
The user must supply the cable to connect the RC2000 to the interface box. On the interface box there is a
CN-GY-RB-3704 RACO 1 inch cable compression fitting reserved for mechanically connecting the
interconnect cable to the interface box. The conduit fitting has a 0.85” to 1.00” diameter opening which the
interconnect cable must pass through to enter the interface. Make sure that the interconnect cable(s)
selected will fit through the opening. Alternatively, the user can replace the liquid tight cable fitting with a
different type of conduit fitting. The interface box is punched with a 1.37” diameter hole for the cable
fitting. This hole is appropriate for 1 inch conduit.
The cable must have 2 pairs of 20 AWG (or heavier) conductors to carry the motor control signals (forward
- stop - reverse). Shielded conductors are not necessary for these signals but if shielded conductors are
available the shield can be used. For shielded motor control conductors, follow the rules given below for
the shielded sensor cables. In addition to the motor control signals a pair of individually shielded triples
with drain wires are necessary for the sensor connections.
Comments to this Manuals